IONIZING AIR BLOWER
| MS-Y0101 TABLE MODEL
IONIZING AIR BLOWER ----[INTRO] |
|
MS-Y0101 TABLE MODEL IONIZING AIR BLOWER It is designed as the
theory of alternating current electrostatic eliminator, belongs to
electrical category.Apply to eliminate electrostatic in a limited
distance, convenient to remove and install.The ionizing air volume
can be adjusted, including high voltage generator. |
|
Specification: |
|
Operating Voltage |
110V/60HZ OR 220V/50HZ |

MS-Y0101 |
|
Current Consumption |
0.25A OR 0.12A |
|
Operating Temperature |
-10~50℃ |
|
Size |
90mm(L)X170mm(W)X260mm(H) |
|
Weight |
3.3Kg |
|
Air Volume |
45~110CFM |
|
Ion Balance |
0V±10V |
|
Air Coverage |
40cm×60cm |
|
Decay tdst Results: |
|
Testing Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃
Test Humidity:75%RH |
|
Distance |
|
300mm |
600mm |
900mm |
|
Decay time |
Positive |
1.2s |
2.5s |
3.9s |
|
Negative |
1.3s |
2.6s |
4.1s |
|
Offset voltage |
Positive |
8V |
5V |
4V |
|
Negative |
-7V |
-6V |
-3V |
| MS-Y0102 SUSPENDED IONIZING
AIR BLOWER----[INTRO] |
|
MS-Y0102 SUSPENDED IONIZING AIR BLOWER, It is designed as the theory
of alternating current electrostatic eliminator, belongs to
electrical category.Apply to eliminate electrostatic in a space. The
double header ionizing air volume can be adjusted, including high
voltage gene-rator. |
|
Specification: |
|
Operating Voltage |
110V/60HZ OR 220V/50HZ |

MS-Y0102 |
|
Current Consumption |
0.9A OR 0.4A |
|
Operating Temperature |
-10~50℃ |
|
Size |
600mm(L)×90mm(W)×170mm(H) |
|
Weight |
7.8Kg |
|
Air Volume |
80~220CFM |
|
Ion Balance |
0V±10V |
|
Air Coverage |
40cm×90cm |
|
Decay tdst Results: |
|
Testing Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃
Test Humidity:75%RH |
|
Distance |
300mm |
600mm |
900mm |
1200mm |
|
Left300mm |
1.3s |
2.4s |
2.8s |
4.9s |
| Center |
2.8s |
1.7s |
3.2s |
3.6s |
|
Right300mm |
1.2s |
2.1s |
3.0s |
4.5s |
| MS-Y0103 SUSPENDED IONIZING
AIR BLOWER----[INTRO] |
|
MS-Y0103 SUSPENDED IONIZING AIR BLOWER, It is designed as the theory
of alternating current electrostatic eliminator, belongs to
electrical category.Apply to eliminate electrostatic in a space. The
triple header ionizing air volume can be adjusted, including high
voltage generator. |
|
Specification: |
|
Operating Voltage |
110V/60HZ OR 220V/50HZ |

MS-Y0103 |
|
Current Consumption |
1.25A OR 0.62A |
|
Operating Temperature |
-10~50℃ |
|
Size |
1100mm(L)×184mm(W)×110mm(H) |
|
Weight |
12.8Kg |
|
Air Volume |
120~330CFM |
|
Ion Balance |
0V±10V |
|
Air Coverage |
40cm×120cm |
|
Decay tdst Results: |
|
Testing Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃
Test Humidity:75%RH |
|
Distance |
300mm |
600mm |
900mm |
1200mm |
|
Left300mm |
1.9s |
2.5s |
5.1s |
8.6s |
| Center |
1.3s |
2.3s |
4.3s |
8.3s |
|
Right300mm |
1.8s |
2.6s |
4.8s |
8.5s |
| MS-Y0104 HORIZONTAL IONIZING
AIR BLOWER----[INTRO] |
|
MS-Y0104 HORIZONTAL IONIZING AIR BLOWER, On the base of design of
ST105A horizontal ioni-zing air blower, it is smaller and more
portable.Can install ionizing equilibrium measurement realtime
supervising and alarming system as request.The ionizing air volume
can be adjusted, including high voltage generator. |
|
Specification: |
|
Operating Voltage |
110V/60HZ OR 220V/50HZ |

MS-Y0104 |
|
Current Consumption |
3.0A OR 1.5A |
|
Operating Temperature |
-10~50℃ |
|
Size |
400mm(L)×220mm(W)×190mm(H) |
|
Weight |
5.8Kg |
|
Air Volume |
70~120CFM |
|
Ion Balance |
0V±10V |
|
Air Coverage |
60cm×120cm |
|
Decay tdst Results: |
|
Testing Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃
Test Humidity:75%RH |
|
Distance |
300mm |
600mm |
900mm |
1200mm |
|
Left300mm |
1.3s |
2.5s |
3.9s |
6.6s |
| Center |
1.1s |
2.2s |
3.6s |
6.5s |
|
Right300mm |
1.2s |
2.3s |
3.8 |
6.3s |
| MS-Y0105 HORIZONTAL IONIZING
AIR BLOWER----[INTRO] |
|
MS-Y0105 HORIZONTAL IONIZING AIR BLOWER, It is designed as the
theory of alternating current electrostatic eliminator, belongs to
electrical category.Flat- wide big air volume design apply to
eliminate electrostatic in a wide space.The ionizing air volume can
be adjusted, including high voltage generator. |
|
Specification: |
|
Operating Voltage |
110V/60HZ OR 220V/50HZ |

MS-Y0105 |
|
Current Consumption |
3.0A OR 1.5A |
|
Operating Temperature |
-10~50℃ |
|
Size |
570mm(L)×220mm(W)×190mm(H) |
|
Weight |
8.5Kg |
|
Air Volume |
70~120CFM |
|
Ion Balance |
0V±10V |
|
Air Coverage |
80cm×120cm |
|
Decay tdst Results: |
|
Testing Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃
Test Humidity:75%RH |
|
Distance |
300mm |
600mm |
900mm |
1200mm |
|
Left300mm |
1.8s |
2.5s |
5.2s |
8.6s |
| Center |
1.3s |
2.2s |
4.3s |
7.5s |
|
Right300mm |
1.7s |
2.3s |
4.8s |
8.3s |
| MS-Y0106 IONIZING AIR
BLOWER----[INTRO] |
|
MS-Y0106 IONIZING AIR BLOWER, is a high efficient, long-distance,
large-area blower type electrostatic eliminator, belongs to
industrial category.Widely used in various mechanical equipment,
including high voltage generator. |
|
Specification: |
|
Operating Voltage |
220V-380V 50/60HZ 3phasc |

MS-Y0106 |
|
Current Consumption |
2.0A OR 1.1A |
|
Operating Temperature |
-10~50℃ |
|
Integrated Power Supply |
7.0kv |
|
Size |
547mm(L)×360mm(W)×230mm(H) |
|
Weight |
16Kg |
|
Air Volume |
350~430CFM |
|
Discharge Time |
< 1 sec(Fan space high) |
|
Air Coverage |
60cm×300cm |
|
|
 |
 |
 |
 |
 |
 |
 |
|