RE    : HELLER MODEL 1809EXL-N2 FORCED HOT AIR CONVECTION

              REFLOW OVEN (NITROGEN)  - LEAD FREE CAPABLE               

               ( BRAND NEW MACHINE )


SPECIFICATIONS             

DIMENSIONS                  

  • Overall Length                                                                 : 183 " (465 cm)

  • Overall Width                                                                   :   54"  (137 cm)

  • Overall Height                                                                  :   63"  (160 cm)

  • Net Weight                                                                       : 3500 lbs (1588 kg)

  • Shipping Weight                                                             : 4500 lbs (2041 kg)

MESH BELT CONVEYOR

  • Height from Floor                                                            : 35.5" +/- 2"

  • Maximum PCB Width                                                     : 10", 15", 18" & 22"

  • Space  required between PCB                                     : 0.0" (0.0 cm)

  • Conveyor Length On-load                                              : 6" (15 cm)

  • Conveyor Length Off-load                                              : 6" (15 cm)

  • Heated tunnel Length                                                      : 105" (254 cm)

  • Process clearance Above Mesh belt                            : 2.3" (5.8 cm)

  • Mesh Belt Pitch                                                               : 0.5" (1.27 cm)

  • Maximum Conveyor Speed                                           : 74"/min (188 cm/min)

  • Conveyor direction                                                          : Left to Right

  • Conveyor Speed control Type                                       : Closed Loop

FORCED CONVECTION ZONES             

  • Top                                                                                   : 8 convection zones + 1 IR

  • Bottom                                                                              : 8 convection zones + 1 IR

  • Heater type                                                                      : instant response open coil

  • Heater Material                                                               : Nichrome

  • Profile change time                                                         : 5-15 min

TEMPERATURE CONTROL

  • Accuracy of Temperature Controller                             : +/- 0.10C

  • Cross-belt Temperature tolerance                                : +/- 2.00C

  • Heater Wattage per zone                                               : 6000 W

  • Temperature Range Standard                                      : 25-3500C

  • Insulation type                                                                  : Calcium silicate

                                                                                                                                  PAGE 2

COOLING SYSTEM

  • Number of Cooling Zone Standard                               : 2 zones

ELECTRIC SUPPLY

  •         Power Input Standard                                                     : 220 volts AC , 3 phase

  •         Breaker size                                                                    : 100 amps @ 220 volts AC

  •         Run Current                                                                      :  50-55  amps @ 220 volts AC

  •         Frequency                                                                        : 50/60 hertz

  •         Sequential Zone turn on                         : standard

INERT ATMOSPHERE

  •         Minimum PPM Oxygen                                                   : 10-25 PPM (depending on pcb size and tunnel opening)

  •         Flexible entrance & exit doors                                       : standard

  •         Nitrogen cooling                                                              : standard

  •         Sample port in reflow                                                      : standard

  •         Typical Nitrogen consumption                                       : < 1000 SCFH (depending on pcb size and tunnel opening)

COMPUTER CONTROL

  •         Pentium II or greater                                                       : standard

  •         Recipe Storage                                                               : greater than 500

  •         14" SVGA Color                                                              : standard

  •         Operating System                                                           : Windows 98

  •         Computer swing arm                                                      : standard

  •         Auto start software                                                          : standard

  •         Data Logging                                                                  : standard

  •         password protection                                                       : standard

SYSTEMS INCLUDES :

SIGNAL LIGHT TOWER

POWERED HOOD LIFT

FIVE THERMOCOUPLE PROFILING

BBU-18 BATTERY BACK-UP

N2-18, NITROGEN INERT OPERATION

WLC-FF GEN. 5 -18, WATERLESS COOLING & FILTERLESS

FLUX FILTRATION SYSTEM (GEN. 5 SYSTEM)

EHC -18 EDGE HOLD CONVEYOR (POWER ADJUST)

LF-18  LEAD FREE ZONE CONFIGURATION

CL-18 CLOSED LOOP NITROGEN CONTROL SYSTEM (INCL. OXYGEN PPM MONITOR)

ULN-18  ULTRA LOW NITROGEN CONSUMPTION  SYSTEM

MB-18 MESH BELT WITH N2 SYSTEM


NET SELL PRICE : US$   E-Mail Us!

NOTE : SPECIFICATIONS OF EDGE HOLD CONVEYOR SYSTEM (OPTION)

  •         Clearance Above Conveyor  Pins                                 : 1.15" (2.9 cm)

  •         Clearance Below Conveyor Pins                                  : 1.15" (2.9 cm)

  •         Length of PCB support pins                                          : 0.187" (4.75 mm)

  •         Minimum PCB width                                                       : 2.0" (5.0 cm)

  •         Maximum PCB width                                                      : 24" (61 cm)